5 - 58
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting value
Setting value buffer
memory address
Item
Value set with peripheral device
Value set with sequence program
Default
value
Axis 1 Axis 2 Axis 3
00 : Positioning complete
00
01 : Continuous positioning control
01
Da.1
Operation
pattern
11 : Continuous path control
11
ABS Linear 1 :
1-axis linear control (ABS)
01
H
INC Linear 1 :
1-axis linear control (INC)
02
H
Fixed-dimension feed 1 :
1-axis fixed-dimension feed control
03
H
ABS Linear 2 :
2-axis linear interpolation control (ABS)
04
H
INC Linear 2 :
2-axis linear interpolation control (INC)
05
H
Fixed-dimension feed 2 :
2-axis fixed-dimension feed control
06
H
ABS Circular interpolation :
Circular interpolation control with
auxiliary point designation (ABS)
07
H
INC Circular interpolation :
Circular interpolation control with
auxiliary point designation (INC)
08
H
ABS Circular right :
Circular interpolation control with center
point designation (ABS, CW)
09
H
ABS Circular left :
Circular interpolation control with center
point designation (ABS, CCW)
0A
H
INC Circular right :
Circular interpolation control with center
point designation (INC, CW)
0B
H
INC Circular left :
Circular interpolation control with center
point designation (INC, CCW)
0C
H
Forward run Speed limited :
Speed control (forward run)
0D
H
Reverse run Speed limited :
Speed control (reverse run)
0E
H
Forward run speed/position :
Speed/position changeover control
(forward run)
0F
H
Reverse run speed/position :
Speed/position changeover control
(reverse run)
10
H
Current value change :
Current value change
11
H
Da.2
Control
method
JUMP command :
JUMP command
20
H
0 : Pr.8 Acceleration time 0
00
1 : Pr.26 Acceleration time 1
01
2 : Pr.27 Acceleration time 2
10
Da.3
Acceleration
time No.
3 : Pr.28 Acceleration time 3
11
0 : Pr.9 Deceleration time 0
00
1 : Pr.29 Deceleration time 1
01
2 : Pr.30 Deceleration time 2
10
P
o
s
it
ioni
ng i
dent
if
ie
r
Da.4
Deceleration
time No.
3 : Pr.31 Deceleration time 3
11
H
Control method
Setting value
b15
b12
b8
b4
b0
0
0
Convert into hexadecimal
Operation pattern
Acceleration
time
Deceleration time
0000
H
1300 2300 3300
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...