12 - 47
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
(d) If the "new acceleration/deceleration time" is set to "0" and the speed is
changed after the "new acceleration/deceleration time" is validated, the
operation will be controlled with the previous "new acceleration/deceleration
time".
Disabled
Enabled
0
0
1000
Speed change
t
V
New acceleration/deceleration
time ( Cd. 33 , Cd. 34 )
Cd.35
Cd.33 New acceleration time value
Cd.34 New deceleration time value
Example
Speed change
Speed change
Acceleration/deceleration time
change during speed change,
enable/disable selection
Controlled with the acceleration/
deceleration time in the parameter
(e) During JOG operation, the acceleration/deceleration time change function
does not function.
POINT
If the speed is changed when an acceleration/deceleration change is enabled, the
"new acceleration/deceleration time" will become the acceleration/deceleration time
of the positioning data being executed. The "new acceleration/deceleration time"
remains valid until the changeover to the next positioning data. (The automatic
deceleration processing at the completion of the positioning will also be controlled
by the "new acceleration/deceleration time".)
(3) Setting the acceleration/deceleration time change function
To use the "acceleration/deceleration time change function", write the data
shown in the following table to the AD75 using the sequence program.
The set details are validated when a speed change is executed after the details
are written to the AD75.
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3
Cd.33
New acceleration
time value
Set the new acceleration time.
1184
1185
1234
1235
1284
1285
Cd.34
New deceleration
time value
Set the new deceleration time.
1186
1187
1236
1237
1286
1287
Cd.35
Acceleration/
deceleration time
change during
speed change,
enable/disable
selection
1
Set "1: Acceleration/deceleration time change
enable".
1188 1238 1288
* Refer to section "5.7 List of control data" for details on the setting details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...