[4-3 Outdoor Unit Electrical Wiring Diagrams ]
- 108 -
HWE1314A
GB
4-3
Outdoor Unit Electrical Wiring Diagrams
(1) PURY-P200, P250, P300, P350, P400YLM-A(1)
PURY-EP200, EP250, EP300, EP350YLM-A
Linear expansion valve (for the control of evaporating temperature)
RSH01/02,RSH1
For current detection
C30~C37
Capacitor (inverter main circuit)
L
Choke coil (for high frequency noise reduction)
SV4a,b,d
Heat exchanger capacity control
R1,5
Resistor
For inrush current prevention
Subcooled liquid refrigerant temperature
Pipe temperature
Outdoor unit heat exchanger capacity control
SV5b
SV1a
21S4a
Symbol
<Symbol explanation>
63H1
63HS1 63LS 72C
CT12,CT22,CT3
LEV5a
DCL
Solenoid valve
For opening/closing the bypass circuit under the O/S
4-way valve(Cooling/Heating switching)
Explanation
Pressure sensor
Pressure switch
High pressure protection for the outdoor unit
Discharge pressure Low pressure
Magnetic relay(inverter main circuit)
Current sensor(AC)
DC reactor
Z25
THHS
TH7
TH6
TH5
TH4
TH3
TB7
TB3
TB1
SV7,SV9
Thermistor
Discharge pipe temperature ACC inlet pipe temperature
OA
temperature
IPM temperature
Function setting connector
Power supply
Indoor/Outdoor transmission cable
Central control transmission cable
Terminal block
For opening/closing the bypass circuit
*1.Single-dotted lines indicate wiring not supplied with the
unit.
*2.Dot-dash lines indicate the control box boundaries. *3.Refer to the Data book for connecting input/output signal connectors. *4.Daisy-chain terminals (TB3) on the outdoor units in the same refrigerant system together
.
*5.Faston terminals have a locking function. Make sure the terminals are securely locked in place after insertion. Press the tab on the terminals to removed them. *6.Control box houses high-voltage parts. Before inspecting the inside of the control box,turn of
f
the power
,keep the unit of
f for at least 10 minutes, and
confirm that the voltage between FT
-P
and FT
-N on
INV Board has dropped to DC20V or less.
SV10,SV1
1
For opening/closing the defrost circuit
TH9,TH1
1
Heat exchanger outlet pipe temperature
*7.Dif
ference of appliance.
P200/250/300/350/400
Model name
*7 do not exist
appliance
EP200/250/300/350
*7 exist
F121 DC700V 4A
T
C151,C152
RSH01/02
12
L3
N
red
CNPS
1
3
2
1
TP1
TP2
TB3
2
3
TB7
M1
M2
M1
M2
S
1
5
12
34
1
2
1
2
1
32
3
4
6
3
6
1
5
3
1
2
2
CN82 blue
1
3 4
CN83 black
L1
L2
3
1
Fan motor (Heat exchanger)
U
V
W
CNINV
7
1
4
34
CN4 black
1
13
231
3
SW001
1
4
CN2
1
12
1
3
3
1
43
2
2
3
1
1
CNSNR
TH4
4
1
1
1
CN21
1
green
2
3
123
321
U
5
2
5
4
3
2
1
1
3
2
1
2
3
1
2
3
1
CN6
21
2
yellow CNPOW
1
654
X10
X12
ON
X08
Unit address setting
CT12
CN5 red
D1
R4
-
Z5
1
+
3
1
6
white
12
34
3
green CN62
CN990 green
CN213 green
CNTYP4
F4 AC250V 6.3A
T
R5
CN201
Z25
TH5
TH6
SWU2
LED1
SW6
10
Control Board
TH3
CN40
63HS1
CN41
TH7
1
5
2
3
4
1
SW4
LED3
5
LEV5a
3
3
SET
UP(SW6-10)
SC-V
CT22
SC-U
V
CN4 blue
red
M
OFF
t
black
CN506
red
CNTYP2
black
6
yellow CN3K
*3
Compressor ON/OFF output Error detection output
TB21
DC12V
CN51
SV5b
CN1A
U
CN2
blue CN3N
1
3
+
3
4
TB1
CN1B
TB7 Power selecting connector
CNVDC
1
IPM
2
5
6
L3
N
DCL
black
72C
white
red
26
ON
OFF
M-NET
power
supply circuit
12
M-NET
Board
Indoor/Outdoor transmission cable
INV Board
red
TB23
TB24
L2
L1
+
ON
1's digit
THHS
CN102
C31,C33, C35,C37
1
4
1
1
W
10's digit
OFF
LED2:Normal operation(Lit)
/ Error(Blink)
CNS2 yellow
CNDC red
red
MS 3~
2
2
C100
*5
LED1:Power supply to
Indoor/Outdoor transmission line
+
black
Central control transmission cable
*6
SC-L1
ON
OFF
FT
-N
R30,R32, R34
Motor
(Compressor)
red CN3S
1
CN04 red
CN43 yellow
1
SC-P2
P
CN61 green
CN202
red
C30,C32, C34,C36
6
N
CN1
LED1:Normal operation(Lit) / Error(Blink)
*4
SC-W
SC-L3
2
CNR
YB
P
63H1
4
1
SW5
10
5
CN3D
1
CPU power supply circuit
black CNAC2
1
*3
ON
OFF
10
SWU1
white
CN212
red
SC-L2
6
2
CN80
CNTYP5
green
LED4:CPU in operation
LED1:Normal operation(Lit) / Error(Blink)
CN801
red
5
°
IPM
4
SC-P1
FT
-P
black
red
DB1
CT3
C1
CNTYP black
black
TB22
SWP1
RSH1
R6
C1
1
FAN Board
63LS
ZNR1
U
L
Noise Filter
2
CN507 black
CN508 blue
3
3
3
6
6
4
CN3 green
SV9
Function setting
LED1 Display setting/ Function setting
72C
Noise filter
Noise filter
6
7
red
Surge absorber
1
2
1
1
CNL
VA
1
F01 AC250V 3.15A
T
MS 3~
white
black
1
CNIT red
L1
L2
L3
N
R31,R33, R35
3
4 1
R1,R5
X05
X13
X06
X14
3
3
5
5
1
1
6
6
CN505
CN509 yellow
1
3
CNAC
CN81 green
12
5
3
4
4
4
CN2
SV1a
SV4b
SV4d
SV4a
21S4a
Power Source 3N~ 50/60Hz 380/400/415V
t°
t°
t°
t°
t°
t°
t°
TH1
1
CNTYP1
black
1
2
TH9
5
X09
SV7
*7
3
1
CN504
SV1
1
3
1
CN503
SV10
X03
yellow
green
X04
CN1
10
black
1
2
Power failure detection circuit
U
ZNR400
1
Содержание PURY-EP200YLM-A
Страница 9: ...viii ...
Страница 13: ... 2 HWE1314A GB ...
Страница 29: ... 1 5 Cautionary notes on installation environment and maintenance 18 HWE1314A GB ...
Страница 31: ... 20 HWE1314A GB ...
Страница 44: ... 2 6 System Connection Example 33 HWE1314A GB 2 Restrictions ...
Страница 58: ... 2 7 Example System with an MA Remote Controller 47 47 HWE1314A GB 2 Restrictions ...
Страница 77: ... 66 HWE1314A GB ...
Страница 105: ... 94 HWE1314A GB ...
Страница 125: ... 4 6 BC Controller Circuit Board Components 114 HWE1314A GB 4 6 2 Four Relay Board 4 6 3 Ten Relay Board ...
Страница 137: ... 126 HWE1314A GB ...
Страница 171: ... 160 HWE1314A GB ...
Страница 227: ... 6 11 Standard Operation Data Reference Data 216 HWE1314A GB ...
Страница 230: ... 219 HWE1314A GB 7 9 9 Error Code 7113 292 7 9 10 Error Code 7117 293 7 9 11 Error Code 7130 294 ...
Страница 231: ... 220 HWE1314A GB ...
Страница 393: ... 8 16 Troubleshooting Problems Using the LED Status Indicators on the Outdoor Unit 382 HWE1314A GB ...
Страница 395: ... 384 HWE1314A GB ...