Parameters
(A) Application parameters
FR-A800
5 - 545
●
The display of the following parameters is changed according to the C42 (Pr. 934)), C44 (Pr. 935),
Pr. 1136, and Pr. 1138 settings.
Example
쑴
Set the following:
Pr. 934 = "500", 20% (4 mA is applied), Pr. 935 = "100", 100% (20 mA is applied).
When the set point=400 and the measured value = 360, the deviation is +40 (>0), but the inverter
recognizes the deviation as –10% (<0). Because of this, operation amount does not increase in the
reverse operation setting.
The operation amount increases when the forward operation is set.
To perform PID output shutoff release at deviation of +40 or higher, set Pr. 577 = "960".
쑶
Pr.
Name
Pr.
Name
131
PID upper limit
1143
Second PID upper limit
132
PID lower limit
1144
Second PID lower limit
133
PID action set point
755
Second PID action set point
553
PID deviation limit
1145
Second PID deviation limit
577
Output interruption cancel level
1149
Second output interruption cancel level
761
Pre-charge ending level
766
Second pre-charge ending level
763
Pre-charge upper detection level
768
Second pre-charge upper detection level
Tab. 5-231:
Influence of C42 (Pr. 934)), C44 (Pr. 935), Pr. 1136, and Pr. 1138 on other parameter displays
0
100%
500
20%
100
400
360
(0%) (25%) (35%)
(100%)
+40
Deviation
Set point
Measured value
* ( ) indicates the deviation value
which the inverter can recognize
Deviation –10 %
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......