Outline dimension drawings
Specifications
8 - 26
Dimensions table
SF-V5RUF
첸
K
1
2
3
5
7
11
15
18
22
—
30
37, 45
SF-V5RUF
첸
K1
—
1
2
3
5
7
11
—
15
18
—
22, 30
SF-V5RUF
첸
K3
—
—
1
2
3
5
7
—
11
15
—
18, 22
SF-V5RUF
첸
K4
—
—
—
—
1
2
3
—
—
5
7
—
Flange No.
FF165
FF215
FF215
FF265
FF265
FF300
FF300
FF350
FF350
FF400
Frame No.
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
Mass [kg]
26.5
37
46
65
70
110
125
160
185
225
270
290
Motor
D
183.6
207
228
266
266
318
318
363
363
406
IE
—
130
141
156
156
207
207
230
230
255
KB
198.5
213
239
256
294
318
362
378.5
416.5
485
KD
27
27
27
27
27
56
56
56
56
90
KL
220
231
242
256
256
330
330
352
352
346
LA
165
215
215
265
265
300
300
350
350
400
LB
130j6
180j6
180j6
230j6
230j6
250j6
250j6
300j6
300j6
350j6
LC
200
250
250
300
300
350
350
400
400
450
LE
3.5
4
4
4
4
5
5
5
5
5
LG
12
16
16
20
20
20
20
20
20
22
LL
402
432
448
484
522
625
669
690
728
823.5
LN
4
4
4
4
4
4
4
4
4
8
LZ
12
14.5
14.5
14.5
14.5
18.5
18.5
18.5
18.5
18.5
Shaft
end
LR
50
60
60
80
80
110
110
110
110
140
Q
50
60
60
80
80
110
110
110
110
140
QK
40
45
45
63
63
90
90
90
90
110
S
24j6
28j6
28j6
38k6
38k6
42k6
42k6
48k6
55m6
60m6
T
7
7
7
8
8
8
8
9
10
11
U
4
4
4
5
5
5
5
5.5
6
7
W
8
8
8
10
10
12
12
14
16
18
Terminal
screw
size
U, V, W
M6
M6
M6
M6
M6
M8
M8
M8
M8
M10
A, B, (C)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
G1, G2
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
Tab. 8-13:
Dimensions table (Unit: mm)
NOTES
Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
The size difference of top and bottom of the shaft center height is
The 400 V class motor has -H at the end of its type name.
0
-0.5
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......