Precautions for maintenance and inspection
Measurement of main circuit voltages, currents and powers
FR-A800
7 - 15
7.2.1 Measurement
of
powers
Use digital power meters (for inverter) for the both of inverter input and output side. Alternatively,
measure using electrodynamic type single-phase wattmeters for the both of inverter input and out-
put side in two-wattmeter or three-wattmeter method. As the current is liable to be imbalanced es-
pecially in the input side, it is recommended to use the three-wattmeter method.
Examples of measured value differences produced by different measuring meters are shown below.
An error will be produced by difference between measuring instruments, e.g. power calculation type
and two- or three-wattmeter type three-phase wattmeter. When a CT is used in the current measuring
side or when the meter contains a PT on the voltage measurement side, an error will also be produced
due to the frequency characteristics of the CT and PT.
I001301E, I001302E
Fig. 7-12:
Differences when measuring power with different instruments
Example of measuring inverter input power
Example of measuring inverter output power
3-wattmeter method (Electro-dynamometer type)
2-wattmeter method (Electro-dynamometer type)
Clip AC power meter
(For balanced 3-phase load)
Clamp-on wattmeter
(Hall device power arithmetic type)
3-wattmeter method (Electro-dynamometer type)
2-wattmeter method (Electro-dynamometer type)
Clip AC power meter
(For balanced 3-phase load)
Clamp-on wattmeter
(Hall device power arithmetic type)
Measurement conditions:
Constant-torque (100%) load,
constant-output at 60 Hz or more. 3.7 kW, 4-pole motor,
value indicated in 3-wattmeter method is 100%
Measurement conditions:
Constant-torque (100%) load,
constant-output at 60 Hz or more. 3.7 kW, 4-pole motor,
value indicated in 3-wattmeter method is 100%
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......