Parameter List
Parameters
5 - 16
M
a
in
te
nanc
e
503
E710
Maintenance timer 1
0 (1 to 9998)
1
0
504
E711
Maintenance timer 1 warning output
set time
0 to 9998, 9999
1
9999
⎯
505
M001
Speed setting reference
1 to 590 Hz
0.01 Hz
60 Hz
50 Hz
S-pa
tt
ern
acce
le
ration
/
deceleration D
516
F400
S-pattern time at a start of acceleration
0.1 to 2.5 s
0.1 s
0.1 s
517
F401
S-pattern time at a completion of
acceleration
0.1 to 2.5 s
0.1 s
0.1 s
518
F402
S-pattern time at a start of deceleration
0.1 to 2.5 s
0.1 s
0.1 s
519
F403
S-pattern time at a completion of
deceleration
0.1 to 2.5 s
0.1 s
0.1 s
⎯
522
G105
Output stop frequency
0 to 590 Hz, 9999
0.01 Hz
9999
⎯
539
N002
MODBUS RTU communication check
time interval
0 to 999.8 s, 9999
0.1 s
9999
USB
547
N040
USB communication station number
0 to 31
1
0
548
N041
USB communication check time
interval
0 to 999.8 s, 9999
0.1 s
9999
C
o
mmunication
549
N000
Protocol selection
0, 1
1
0
550
D012
NET mode operation command source
selection
0, 1, 9999
1
9999
551
D013
PU mode operation command source
selection
1 to 3, 9999
1
9999
⎯
552
H429
Frequency jump range
0 to 30 Hz, 9999
0.01 Hz
9999
PID
con
tr
o
l
553
A603
PID deviation limit
0.0 to 100%, 9999
0.1%
9999
554
A604
PID signal operation selection
0 to 3, 10 to 13
1
0
Cu
rr
e
n
t a
v
e
ra
g
e
va
lu
e
m
o
n
ito
r
555
E720
Current average time
0.1 to 1 s
0.1 s
1 s
556
E721
Data output mask time
0 to 20 s
0.1 s
0 s
557
E722
Current average value monitor signal
output reference current
0 to 500 A
0.01 A
Rated inverter
current
0 to 3600 A
0.1 A
⎯
560
A712
Second frequency search gain
0 to 32767, 9999
1
9999
⎯
561
H020
PTC thermistor protection level
0.5 to 30 kΩ, 9999
0.01 kΩ
9999
⎯
563
M021
Energization time carrying-over times
(0 to 65535)
1
0
⎯
564
M031
Operating time carrying-over times
(0 to 65535)
1
0
Sec
o
nd
mot
o
r
co
nstants
569
G942
Second motor speed control gain
0 to 200%, 9999
0.1%
9999
Multiple
ratin
g
570
E301
Multiple rating setting
0 to 3
1
2
1,2
⎯
571
F103
Holding time at a start
0 to 10 s, 9999
0.1 s
9999
⎯
573
A680
4 mA input check selection
1 to 4, 9999
1
9999
T052
⎯
574
C211
Second motor online auto tuning
0 to 2
1
0
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (15)
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......