Appendix
For customers using HMS network options
FR-A800
A - 39
A.4
For customers using HMS network options
A.4.1
List of inverter monitored items
The following items can be set using a communication option.
16bit data
No.
Description
Unit
Type
Read/write
H0000 No
data
⎯
⎯
⎯
H0001 Output
frequency
0.01Hz unsigned
R
H0002 Output
current
0.01A/0.1A
unsigned
R
H0003 Output
voltage
0.1V unsigned
R
H0004 reserved
⎯
⎯
⎯
H0005
Frequency setting value
0.01Hz
unsigned
R
H0006 Motor
speed
1r/min unsigned
R
H0007 Motor
torque
0.1% unsigned
R
H0008
Converter output voltage
0.1V
unsigned
R
H0009
Regenerative brake duty
0.1%
unsigned
R
H000A
Electric thermal relay function load factor
0.1%
unsigned
R
H000B
Output current peak value
0.01A/0.1A
unsigned
R
H000C
Converter output voltage peak value
0.1V
unsigned
R
H000D Input
power
0.01kW/0.1kW
unsigned
R
H000E Output
power
0.01kW/0.1kW
unsigned
R
H000F
Input terminal status
⎯
⎯
R
H0010
Output terminal status
⎯
⎯
R
H0011 Load
meter
0.1% unsigned
R
H0012 Motor
excitation
current
0.01A/0.1A
unsigned
R
H0013 Position
pulse
1
unsigned
R/W
H0014 Cumulative
energization
time
1h
unsigned
R
H0015 reserved
⎯
⎯
⎯
H0016 Orientation
status
1
unsigned
R
H0017
Actual operation time
1h
unsigned
R
H0018
Motor load factor
0.1%
unsigned
R
H0019 Cumulative
power
1kWh unsigned
R
H001A
Position command (lower 16 bits)
1
signed
R
H001B
Position command (upper 16 bits)
H001C
Current position (lower 16 bits)
1
signed
R
H001D
Current position (upper 16 bits)
H001E
Droop pulse (lower 16 bits)
1
signed
R
H001F
Droop pulse (upper 16 bits)
H0020 Torque
order
0.1% unsigned
R
H0021
Torque current order
0.1%
unsigned
R
H0022 Motor
output
0.1kW unsigned
R
H0023 Feedback
pulse
1
unsigned
R
H0024 to
H0025
reserved
⎯
⎯
⎯
H0026
Trace status
—
unsigned
R
H0027
reserved
—
—
—
H0028
PLC function user monitor 1
—
unsigned
R
H0029
PLC function user monitor 2
—
unsigned
R
Tab. A-4:
Inverter monitored items (16bit data) (1)
Содержание FR-A800
Страница 2: ......
Страница 4: ......
Страница 22: ...Contents XVIII ...
Страница 30: ...Related manuals Introduction 1 8 ...
Страница 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Страница 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 934: ...Check first when you have a trouble Protective functions 6 46 ...
Страница 954: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 1030: ...EC Declarations of Conformity Appendix A 46 A 5 EC Declarations of Conformity A 5 1 Low Voltage Directive ...
Страница 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Страница 1032: ...EC Declarations of Conformity Appendix A 48 ...
Страница 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Страница 1034: ...EC Declarations of Conformity Appendix A 50 ...
Страница 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Страница 1036: ...EC Declarations of Conformity Appendix A 52 ...
Страница 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Страница 1038: ...EC Declarations of Conformity Appendix A 54 ...
Страница 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Страница 1040: ...EC Declarations of Conformity Appendix A 56 ...
Страница 1041: ......