Chapter 4: Specifications
Four-Port Loop Start Module
Page 4-30
Inter-Tel
®
5000 Installation Manual – Issue 2.4, May 2008
Four-Port Loop Start Module
The four-port loop start module (LSM-4) supports four CO [local exchange] trunks. The LSM-4
functions the same as the LSM-2. For complete installation instructions, see “Installing a Four-
Port Loop Start Module (LSM-4)” on
page 5-42
. For programming refer to
Inter-Tel 5000
Features and Programming Guide
(part no. 580.8006).
Basic Rate Module
The Basic Rate Module (BRM-S) provides Basic Rate S/T interface ISDN service for
communication and is available only in the Inter-Tel Europe market. Each of the two BRI ports
consists of two bearer (B) channels and one data (D) channel with High-level Data Link Control
(HDLC) support. Each BRM-S module in the chassis supports a total of four BRI trunks.
The ports provide full I.430 ITU S/T ISDN support for trunks (TE mode), but does not support
stations (NT) mode. The BRM-S does not support video conferencing or BRI devices and
endpoints.
Four-Port Single Line Module Characteristics
Only one SLM-4 can be installed in an Inter-Tel 5000 Base Server.
The Single Line (SL) application installs as a part of the Inter-Tel 5000 Version–Release suite of
software packages, along with other application packages that support SLM-4 functionality,
such as DB Programming, Call Processing, etc.
The SLM-4:
•
Is hot-swappable.
•
Is designed to be inserted into one of the three bays on the back side of the Inter-Tel 5000
Base Server. The form factor used for the SLM-4 is the same as used for the T1M or T1M-
2, LSM-2, LSM-4, and BRM-S modules.
•
Supports two green status LEDs. One shows ONLINE status, and the other shows the
ready to REMOVE status. The SLM-4 provides two RJ-14 jacks, each wired to USOC
T568A specifications. Together, the two jacks support four single line analog endpoints.
•
Does
not
require software feature licensing.
•
Does
not
operate on a v1.x system. If you plug an SLM-4 into a v1.x system, a warning
message appears and Message Print indicates the board will not come online.
•
Does
not
support dial pulse dialing.
•
Does
not
respond to the Auto Equip feature—SLM-4 modules must be programmed
manually in DB Programming. For instructions, refer to the
Inter-Tel 5000 Features and
Programming Guide
(part no. 580.8006).
IMPORTANT
Basic Rate Interface (BRI) capability is supported only in Inter-Tel Europe
installations.
Содержание Inter-Tel 5000
Страница 1: ...Inter Tel 5000 M I T E L Installation and Maintenance Manual ...
Страница 2: ......
Страница 3: ...Issue 2 4 May 2008 Inter Tel 5000 Installation and Maintenance Manual Part Number 580 8000 ...
Страница 4: ......
Страница 6: ......
Страница 20: ......
Страница 62: ......
Страница 366: ......
Страница 432: ......
Страница 467: ......
Страница 468: ...Part No 580 8000 Issue 2 4 May 2008 A691 9111A ...