Chapter 4 Installation
4-7
1
2
2
4
5
6
Connection
The size of electrical connection, hydraulic connection, pneumatic connection (if any) should be appropriately performed
in accordance with the technical data table described in this manual, taking into consideration the durability of the
equipment.
To make electrical connections, follow the general installation rules for preparation and commissioning.
Specified connection should be done by a qualified and authorized personnel.
Electrical connection
Electrical construction is required to supply power to this unit. Ask the electric construction contractor for construction.
This machine requires a control cabinet connection to the main power supply. Also, it must be connected to the
switchboard in an appropriate state.
With the main network, the following power needs to be reliably supplied to this unit.
Pneumatic connection
This machine must be connected to the pneumatic system. The required outer diameter of the tube is 10 [mm], the
required inner diameter is 8 [mm], and this tube is inserted into the bulkhead connector properly treated beforehand on the
bottom of this machine.
Make sure that the route of the tube does not obstruct traffic of people and vehicles.
Provide a refill tube with two valves (1/2 inch recommended diameter). This tube stops the air supply of this machine and
discharges it during maintenance work.
The specifications of the compressor are as follows.
• “Qualified and authorized personnel” means an employee who has experienced special courses and
training, has experience of installation, trial operation, maintenance of this machine, and recognizes rules
on accident prevention. Qualified and authorized personnel must receive first aid training.
• Before connecting the power supply, shut off the main power supply of the department that installs this
machine.
Table
Feature
Data
►
Voltage
380 [VAC] ±10% 3-phase 5 lines (L1, L2, L3, N, PE)
►
Frequency
50 [Hz] ±1%, 60 [Hz] ±1%
►
Breaker
3-phase 4 lines 380V, 30A
• Before making an electrical connection, make sure that the main power supply of the switchboard
connecting to this machine is turned off.
Procedure
Electrical connection
S
Mode
Key
Indication
Step
Reference
1
In this machine, it is necessary to connect the control cabinet
to the main power supply. This should be done with proper
network grounding.
2
Due to the main network, power must be supplied reliably to
this machine.
3
Open the electrical panel cover with the appropriate keys.
End of procedure
Table 4.7.2
Feature
Data
►
Minimum pressure:
6 [Bar]
►
Maximum pressure:
8 [Bar]
►
Air:
Dry air
Содержание ML Tiger-1800B MKII
Страница 3: ...ii 1 2 2 4 5 6 ...
Страница 6: ...v Troubleshooting 9 5 Dismantling 9 27 ...
Страница 25: ...Chapter 1 Introduction 1 19 1 2 3 4 5 6 M915601 PC outlet rated label ...
Страница 26: ...Chapter 1 Introduction 1 20 ...
Страница 38: ...2 12 Chapter 2 Outline explanation ...
Страница 50: ...4 10 Chapter 4 Installation ...
Страница 120: ...Chapter 6 Basic usage 6 66 ...
Страница 140: ...Chapter 7 Operation Adjustment and Maintenance 7 20 ...
Страница 174: ... MIMAKI ENGINEERING CO LTD 2020 IG MM Tiger Products Install Pack 2 04 ...