Chapter 9 MAINTENANCE
9-26
MDC Command_Error
C2 01
0
C201:00(ZZZZZZZZ)MG Command ERROR
Received undefined
MG command
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If it appears again, contact
your local distributor, our
sales office, or service
center.
MDC Print_Error
C3 01
2
C301:00(ZZZZZZZZ)File read ERROR
Cannot read the
specified file.
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If it appears again, contact
your local distributor, our
sales office, or service
center.
C3 02
0
C302:00(ZZZZZZZZ)Parameter is not set
Operating parameter
does not exist.
C3 03
0
C303:00(ZZZZZZZZ)Parameter illegal
ERROR
Invalid operation
parameter
C3 04
2
C304:00(ZZZZZZZZ)TIFF read ERROR
TIFF file reading failure Data created with RIP
software may be corrupted.
Check the output target
model and printing
conditions, and create the
data again.
C3 05
2
C305:00(ZZZZZZZZ)Mask ERROR
Mask creation failure
C3 06
2
C306:00(ZZZZZZZZ)PSTUS file read ERROR
Invalid print condition
value
MDC Prm_Error
C4 01
2
C401:00(ZZZZZZZZ)Control Data read
ERROR
Error reading control
data
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If it appears again, contact
your local distributor, our
sales office, or service
center.
C4 02
2
C402:00(ZZZZZZZZ)Control Data download
ERROR
Control data download
error
MDC Config_Error
C8 01
2
C801:00(Z)Target does not exist
Z indicates the number of the Firmware that
could not be detected.
1 ~ 8 : PEFW
9 : IOFW
Target does not exist.
The machine settings are not
correct. Contact your local
distributor, our sales office, or
service center.
C8 02
2
C802:00(Z)PCB composition ERROR
Z indicates the configuration error Firmware
number.
1 ~ 8 : PEFW
9 : IOFW
Machine configuration
error
C8 03
2
C803:00(ZZZZZZZZ)Version ERROR
Version error
The version of the units that
configures this machine is
incorrect. Contact your local
distributor, our sales office, or
service center.
Error
No.
Error
level
Error displayed
Cause
Measures
Содержание ML Tiger-1800B MKII
Страница 3: ...ii 1 2 2 4 5 6 ...
Страница 6: ...v Troubleshooting 9 5 Dismantling 9 27 ...
Страница 25: ...Chapter 1 Introduction 1 19 1 2 3 4 5 6 M915601 PC outlet rated label ...
Страница 26: ...Chapter 1 Introduction 1 20 ...
Страница 38: ...2 12 Chapter 2 Outline explanation ...
Страница 50: ...4 10 Chapter 4 Installation ...
Страница 120: ...Chapter 6 Basic usage 6 66 ...
Страница 140: ...Chapter 7 Operation Adjustment and Maintenance 7 20 ...
Страница 174: ... MIMAKI ENGINEERING CO LTD 2020 IG MM Tiger Products Install Pack 2 04 ...