How to Modify the dm.config File to Change Camera and System Assignments
GigE Net
w
ork
Configuration
A
Getting Started with Visionscape GigE Cameras
A-19
11:19:13 Channel 0 (Filter Driver): Microscan VISIONSCAPE
CMG20 (1624x1236) MAC="00-06-BE-00-09-4A" IP="192.168.254.3"
Connected
11:19:13 Channel 1 (Filter Driver): Microscan VISIONSCAPE
CMG20 (1624x1236) MAC="00-06-BE-00-09-4B" IP="192.168.254.2"
Connected
11:19:13 Creating SW System 1: SoftSys1
11:19:15 Creating IO Server for System GigEVision1
11:19:16 Creating IO Server for System SoftSys1
If you look at the FrontRunner device bar you will see that there is still
only one GigE device listed:
Create a new job and bring up the editor. Click on the vision system step
on the left and you will see something similar to that shown below:
There are the two cameras both now available for use in the new job.
Suppose you want to break your cameras down so that, instead of all
being part of one big system, they are on separate systems. Why might
you want to do this? Maybe it makes more sense to your physical layout
this way. For example, if you have one Visionscape system with four
cameras each monitoring a process on four separate lines, then you
might want to stop one line and change the job being run while still