Appendix
A
GigE Network Configuration
A-32
Getting Started with Visionscape GigE Cameras
Go to
My Computer\HKEY_LOCAL_MACHINE\SOFTWARE
\Visionscape\GigEVision\Camera_0
You will actually have Camera_0, Camera_1, Camera_2 and Camera_3
directories – these all have the same things inside. You’ll need to repeat
the procedure for Camera_0 on all 4 cameras.
The two parameters
InterPacketDelay
and
PacketSize
are both set to 0,
which tells Visionscape to use its default values. The first thing you need
to do is set the PacketSize to 8192. To do this, right-click on
PacketSize
and select
Modify
. You’ll see the following: