A-26
Getting Started with Visionscape GigE Cameras
If the original camera is no longer required, delete it by erasing the first
line in the GigEVision1 assignments as follows:
Before
<Devices>
<Device name="GigEVision1" devClass="GigE">
<Assignments>
<Assignment type="ACQ" uid="2ca5cfd1-14c2-45dd-b692-
9a2948d18361" />
<Assignment type="ACQ" uid="07a05837-f79e-4827-8773-
399c72bb1d63" />
</Assignments>
</Device>
<Device name="SoftSys1" devClass="Software" />
</Devices>
After
<Devices>
<Device name="GigEVision1" devClass="GigE">
<Assignments>
<Assignment type="ACQ" uid="07a05837-f79e-4827-8773-
399c72bb1d63" />
</Assignments>
</Device>
<Device name="SoftSys1" devClass="Software" />
</Devices>
You could leave the resources entry in the file but it is cleaner to delete it
(make sure you delete the correct one – use the uid from the original
camera from the line you just deleted).
Before
<Resources>
<Resource uid="2ca5cfd1-14c2-45dd-b692-9a2948d18361"
type="GigE_Camera" MACAddress="00-06-BE-00-09-4B">
<gige>
<CameraID>TL=>GevTL , INT=>FD::MAC->00-1B-21-0A-0C-
72::National Instruments GigE Vision Adapter - Packet Scheduler
Miniport , DEV=>::MAC->00-06-BE-00-09-4B::Baumer
Optronic::VISIONSCAPE CMG20</CameraID>
<IPAddress>192.168.254.2</IPAddress>
<MACAddress>00-06-BE-00-09-4B</MACAddress>
<VendorName>Microscan</VendorName>
<ResolutionX>1624</ResolutionX>
<ResolutionY>618</ResolutionY>
<ModelName>VISIONSCAPE CMG20</ModelName>
</gige>
</Resource>
<Resource uid="07a05837-f79e-4827-8773-399c72bb1d63"
type="GigE_Camera" MACAddress="00-06-BE-00-09-4A">
<gige>
<CameraID>TL=>GevTL , INT=>FD::MAC->00-1B-21-0A-0C-
72::National Instruments GigE Vision Adapter - Packet Scheduler