Tutorial 4 — Using Measurement Tools in an Inspection
Advanced T
ool
Tu
to
ri
al
s
3
Getting Started with Visionscape GigE Cameras
3-39
On the properties page, observe that the Nominal Distance is set to
the output value of the above Pin to Pin Distance, the To/- is
set to be the value that is 5% of the Nominal Distance.
58.
Highlight Left Pin to Center Distance tolerance (left pane).
59.
In the Properties pane, set the following Left Pin to Center Distance
tolerance parameters:
–
Input Datum — Left to Center.Pt-Pt Distance
–
With Tolerance — 5% Nominal
60.
Minimize the Step Tree Editor.
61.
Click .
On the properties page, observe that the Nominal Distance is set to
the output value of the above Left Pin to Center Distance, the
To/- is set to be the value that is 5% of the Nominal Distance.
62.
Highlight Right to Center and click
.
63.
In the Properties (Figure 3–29), set Graphics Level to Show
Graphics.
64.
To select the reference for Point1, click in the area to the right of the
blue arrow (Figure 3–29), and click on the three dots, which displays
the Select Reference window, as shown in Figure 3–30.
FIGURE 3–29.
Select Reference Button