How to Modify the dm.config File to Change Camera and System Assignments
GigE Net
w
ork
Configuration
A
Getting Started with Visionscape GigE Cameras
A-37
The filter driver requires no setup whatsoever. Clicking on the TCP/IP
Properties button will bring up the following dialog:
There is usually no need for cameras to be on a DHCP network, so
choose a static address that starts with 192.168.x.x. 192.168 is reserved
for private networks. In the picture above the address is set to
192.168.254.2 with the subnet mask set to 255.255.255.0. The mask
means that all devices connected to the NIC should have addresses that
start with 192.168.254.x. It is recommended that you steer clear of using
any address that ends with .1 (for instance 192.168.254.1) as this is
sometimes used by networks for gateways (devices that convert one sort
of protocol to another).
You should also optimize the NIC.
How to Set Up a Multiple-Camera
System
covered setting up the advanced parameters for the NIC (jumbo
packets, receive descriptors, etc.). Make sure you do this for best
performance.
Once you have done all this you can connect your camera directly or plug
in a switch and then connect cameras to that switch. As they come out of