KE300A Inverter Function Parameter List
74
Function
code
Name
Detailed instruction
Factory
default
Modify
PP-04
Function code
modification attribute
0: Disable
1: Enable
0
○
A0 Group: Torque Control Parameters
A0-00
Speed/torque control
mode selection
0: Speed control
1: Torque control
0
◎
A0-01
Torque setting source
selection in torque control
mode
0: Keypad (A0-03)
1: AI1
2: AI2
3: Keypad potentiometer
4: High speed pulse HDI
5: Communication
6: Min (AI1,AI2)
7: Max (AI1,AI2)
0
◎
A0-03
Torque setting throught
keypad in torque control
mode
-200.0% ~ 200.0%
150.0%
○
A0-04
Torque filter time
0.00s ~ 10.00s
0.00s
○
A0-05
Forward maximum
frequency in torque
control mode
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
A0-06
Reverse maximum
frequency in torque
control mode
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
A0-07
Acc time in torque control
mode
0.00s ~ 36000s
0.00s
○
A0-08
Dec time in torque control
mode
0.00s ~ 36000s
0.00s
○
A9 Group: Special Function
A9-00
Water supply function
0: Disable
1: Enable
0
◎
A9-01
Auxiliary pump 1
0: Disable
1: Enable
0
◎
A9-02
Auxiliary pump 1 Start
and stop delay
0.0
~
3600.0S
0
○
A9-03
Auxiliary pump 2
0: Disable
1: Enable
0
◎
A9-04
Auxiliary pump 2 Start
and stop delay
0.0
~
3600.0S
0
○
A9-05
Auxiliary pump 3
0: Disable
1: Enable
0
◎
A9-06
Auxiliary pump 3 Start
and stop delay
0.0
~
3600.0S
0
○