KE300A Inverter Parameter Description
163
Code
Name
Range
U0-44
DI input status visual display 2
-
U0-44 displays whether intuitive display function 41-59 are valid or not.
There are 5 digital tubes on keypad. Every digital tube has 8 segments, and each segment indicates a
certain function selection. Digital tubes from left to right represent intuitive display function 41-48, 49-56,
57-59.
NOTE: U0-33 and U0-34 are testing codes for manufacturers.
Code
Name
Range
U0-45
Reserved
-
……
……
-
U0-58
Reserved
-
Code
Name
Range
U0-59
Setting frequency
-100%~100%
U0-60
Running frequency
-100%~100%
U0-59 displays current setting frequency.
U0-60 displays current running frequency.
100% is corresponding to Max. frequency (P0-10).
Code
Name
Range
U0-61
Inverter status
0-65535
U0-61 displays information of inverter running status. Take the following as reference.
U0-61
Combination of bit 0 & bit 1
Combination of bit 2 & bit 3
Bit4
0: stop
1:Forward
2:Reverse
0: constant speed
1: acceleration
2:Deceleration
0: The voltage of DC bus is
normal
1: under voltage
NOTE: A digital tube is corresponding to one bit above.