KE300A Inverter Parameter Description
158
Bit0
Bit1
Bit2
Bit3
DI1
DI2
DI3
DI4
Bit4
Bit5
Bit6
Bit7
DI5
DI6
DI7
-
Code
Name
Range
U0-08
DO output status
0
~
1023
U0-07 displays the digital value output terminal state which can be expressed by a 8-bit binary code; if the
inverter detects that the output of corresponding terminal is high level (closed), then this bit is set to "1", if
the output of corresponding terminal is low level (open), then the bit is set to "0". The relationship between
Digital value output terminal and binary code is shown below.
Bit0
Bit1
Bit2
Bit3
DO3
Relay 1
Relay 2
DO1
Bit4
Bit5
Bit6
Bit7
DO2
-
-
-
Code
Name
Range
U0-09
AI1 Voltage
-10
~
10V
U0-09 displays the input voltage of AI1.
Code
Name
Range
U0-10
AI2 Voltage
-10
~
10V
U0-10 displays the input voltage of AI2.
Code
Name
Range
U0-11
Radiator temperature
-20
~
100
℃
U0-11 displays the current temperature of radiator.
Code
Name
Range
U0-12
Count value
-
U0-12 displays the current value of counter.
Code
Name
Range
U0-13
Length value
-
U0-13 displays the current value of length.