KE300A Inverter Function Parameter List
50
Function
code
Name
Detailed instruction
Factory
default
Modify
1: A - B
2: Max (A, B)
3: Min (A, B)
P0-08
Keypad reference
frequency
0.00Hz ~ maximum frequency:P0-10
50.00Hz
○
P0-09
Running direction
selection
0: Forward
1: Reverse
0
○
P0-10
Maximum frequency
50.00Hz ~ 300.00Hz
50.00Hz
◎
P0-11
Frequency source
upper limit
0: P0-12
1: AI1
2: AI2
3:
Keypad potentiometer
4: HDI
5: Communication
0
◎
P0-12
Frequency upper limit
P0-14 (frequency lower limit) ~ P0-10
(max. frequency)
50.00Hz
○
P0-13
Frequency upper limit
offset
0.00Hz ~ P0-10 (max. frequency)
0.00Hz
○
P0-14
Frequency lower limit
0.00Hz ~ P0-12 (frequency upper limit)
0.00Hz
○
P0-15
Carrier frequency
1.0kHz ~ 16.0kHz
Model
depend
○
P0-16
Carrier frequency
adjusting according to
temperature
0: No
1: Yes
1
○
P0-17
Acceleration time 1
0.01s ~ 36000s
Model
depend
○
P0-18
Deceleration time 1
0.01s ~ 36000s
Model
depend
○
P0-19
ACC/DEC time unit
0: 1s
1: 0.1s
2: 0.01s
1
◎
P0-21
Auxiliary frequency
source offset frequency
when combination
0.00Hz ~ P0-10 (max. frequency)
0.00Hz
○
P0-22
Frequency command
resolution
1: 0.1Hz
2: 0.01Hz
2
◎
P0-23
Digital setting frequency
storage selection when
stop
0: Not store
1: Store
1
○
P0-24
Reserved
●
P0-25
ACC/DEC time
reference frequency
0: P0-10 (max. frequency)
1: Setting frequency
0
◎