KE300A Inverter Function Parameter List
63
Function
code
Name
Detailed instruction
Factory
default
Modify
P8-30
Any arrival frequency
detection value 1
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
P8-31
Any arrival frequency
detection amplitude 1
0.0% ~ 100.0% (maximum frequency)
0.0%
○
P8-32
Any arrival frequency
detection value 2
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
P8-33
Any arrival frequency
detection amplitude 2
0.0% ~ 100.0% (maximum frequency)
0.0%
○
P8-34
Zero-current
detection level
0.0% ~ 300.0%
100.0% corresponds to motor rated
current
5.0%
○
P8-35
Zero-current detection
delay time
0.01s ~ 360.00s
0.10s
○
P8-36
Output current over
limit value
0.0% (No detection)
0.1% ~ 300.0% (motor rated current)
200.0%
○
P8-37
Output current over limit
detection delay time
0.00s ~ 360.00s
0.00s
○
P8-38
Any arrival current 1
0.0% ~ 300.0% (motor rated current)
100.0%
○
P8-39
Any arrival current 1
amplitude
0.0% ~ 300.0% (motor rated current)
0.0%
○
P8-40
Any arrival current 2
0.0% ~ 300.0% (motor rated current)
100.0%
○
P8-41
Any arrival current 2
amplitude
0.0% ~ 300.0% (motor rated current)
0.0%
○
P8-42
Timing function selection
0: Invalid
1: Valid
0
○
P8-43
Timing running time
selection
0
:
P8-44
1
:
AI1
2
:
AI2
3
:
Keypad potentiometer
Analog input scale corresponds to
P8-44
0
○
P8-44
Timing running time
0.0Min ~ 3600.0Min
0.0Min
○
P8-45
AI1 input voltage
protection lower limit
0.00V ~ P8-46
3.10V
○
P8-46
AI1 input voltage
protection upper limit
P8-45 ~ 10.00V
6.80V
○
P8-47
Module temperature
arrival
0
℃
~ 100
℃
75
℃
○
P8-48
Cooling fan control
0: Fan runs when inverter running
1: Fan always runs
0
○
P8-49
Wake up frequency
0.0 ~ PA-04 (PID given feedback
0.0
○