KE300A Inverter Parameter Description
113
Group P7 Keypad and Display
P7-00
Inverter rated power
Factory default
Model depend
Setting range
0.1kW~1000.0kW
Display inverter rated power.
P7-01
QUICK/JOG function selection
Factory default
0
Setting range
0
Invalid
1
Switching between keypad command and remote command
(terminal command and communication command)
2
FDW/REV Switching
3
Forward Jog
4
Reverse Jog
QUICK/JOG
is a multifunctional key, whose function can be defined by the value
0: This key is invalid
1: Switching between keyboard command and remote operation. It refers to switching of command source,
switching between the current command source and the keyboard control (local operation). If the current
command source is keyboard control, this key is invalid.
2: Press QUICK/JOG, the running direction of inverter will change. It is only valid when keypad command is
valid.
3: It can realize forward jog via QUICK/JOG key.
4: It can realize reverse jog via QUICK/JOG key.
P7-02
STOP/RST function selection
Factory default
1
Setting range
0
Valid when keypad control
1
Always valid