KE300A Inverter Function Parameter List
59
Function
code
Name
Detailed instruction
Factory
default
Modify
P6-01
VF 0Hz output mode
0: No output
1: With output
0
○
P6-02
Overmodulation selection
Units place: Overmodulation option
0: Disable
1: Enable
Tens place: Deep overmodulation
option
0: Disable
1: Enable
01
○
P6-03
Start frequency
0.00Hz ~ 10.00Hz
0.00Hz
○
P6-04
Start frequency
holding time
0.0s ~ 100.0s
0.0s
◎
P6-05
DC braking current before
start/pre-excitation
current
0% ~ 100%
0%
◎
P6-06
DC braking time before
start/pre-excitation time
0.0s ~ 100.0s
0.0s
◎
P6-07
ACC/DEC mode
0: Linear ACC/DEC
1: S-curve ACC/DEC A
2: S-curve ACC/DEC B
0
◎
P6-08
Time of S curve's start
part
0.0% ~ (100.0% ~ P6-09)
30.0%
◎
P6-09
Time of S curve's end part
0.0% ~ (100.0% ~ P6-08)
30.0%
◎
P6-10
Stop mode
0: Deceleration to stop
1: Coast to stop
0
○
P6-11
DC braking start
frequency after stop
0.00Hz ~ P0-10 (maximum frequency)
0.00Hz
○
P6-12
DC braking delay time
after stop
0.0s ~ 100.0s
0.0s
○
P6-13
DC braking current
after stop
0% ~ 100%
0%
○
P6-14
DC braking time
after stop
0.0s ~ 100.0s
0.0s
○
P6-15
Braking usage ratio
0% ~ 100%
100%
○
P7 Group: Keypad and Display
P7-00
Inverter rated power
0.1kW~1000.0kW
Model
depend
●
P7-01
QUICK/JOG
function selection
0: Invalid
1: Switching between keypad
command and remote command
(terminal command and
communication command)
0
◎