KE300A Inverter Parameter Description
86
Group P1 Motor Parameters
P1-00
Motor type
Factory default
0
Setting range
0
Common asynchronous motor
1
Variable frequency asynchronous motor
P1-01
Motor rated power
Factory default
Model depend
Setting range
0.1kW ~ 1000.0kW
P1-02
Motor rated voltage
Factory default
Model depend
Setting range
1V ~ 2000V
P1-03
Motor rated current
Factory default
Model depend
Setting range
0.01A ~ 655.35A (I
nverter power≤55kW)
0.1A ~ 6553.5A (Inverter power
>
55kW)
P1-04
Motor rated frequency
Factory default
Model depend
Setting range
0.01Hz ~ P0-10 (maximum frequency)
P1-05
Motor rated speed
Factory default
Model depend
Setting range
1rpm ~ 65535rpm
1. Please set the parameters correctly according to the motor nameplate.
2. In order to achieve superior control performance, please perform motor parameters autotuning. The
accuracy of autotuning is closely related to the correct setting of the rated motor parameters.
P1-06
Motor stator resistance
Factory default
Model depend
Setting range
0.001
Ω ~ 65.535Ω (Inverter power≤55kW)
0.0001Ω ~ 6.5535Ω (Inverter power
>
55kW)
P1-07
Motor rotor resistance
Factory default
Model depend
Setting range
0.001Ω ~ 65.535Ω (Inverter power≤55kW)
0.0001Ω ~ 6.5535Ω (Inverter power
>
55kW)
P1-08
Motor leakage inductive
Factory default
Model depend
Setting range
0.01mH ~ 655.35mH (I
nverter power≤55kW)
0.001mH ~ 65.535mH (Inverter power
>
55kW)
P1-09
Motor mutual inductive
Factory default
Model depend
Setting range
0.1mH ~ 6553.5mH (I
nverter power≤55kW)
0.01mH ~ 655.35mH (Inverter power
>
55kW)
P1-10
Motor current without load
Factory default
Model depend
Setting range
0.01A ~ P1-03 (I
nverter power≤55kW)
0.1A ~ P1-03 (Inverter power
>
55kW)
P1-06 ~ P1-10 are motor parameters, which cannot be found on the motor nameplate, and are obtained
via the inverter autotuning. The static autotuning only can obtain P1-06 ~ P1-08. The rotation autotuning
not only can obtain P1-06 ~ P1-10, but also can get current loop PI parameter, etc.
When P1-01 or P1-02 changed, the inverter will change P1-06 ~ P1-10 automatically, and restore P1-06 ~