18
PARAMETER
DESCRIPTION
FAULT CODE
1015
FAULT MESSAGE Loco over speed. Move Master Controller Handle to IDLE
RESTRICTIONS
Motoring Prohibited.
ALARM BELL
30 Seconds.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
RECOVERY
Autometic when loco speed is below the set limit and Master Handle is
brought to IDLE.
PROBABLE
CAUSES
Locomotive speed is high.
FAULT
ISOLATION
Reduce the notch and work to maintain the locomotive speed with in
the set limit.