Table 201. Troubleshooting Electrical System (Cont.)
Symptom
Corrective Action
Probable Trouble
Starter
−
generator fails to supply
charging current with engine
operating
Circuit breaker out
Reset circuit breaker.
Reverse current relay defective or
*GCU
Replace reverse current relay or
*GCU.
Excessive discharge rate
Check for cause of excessive
discharge rate.
Charging rate to high
Adjust voltage regulator or *GCU.
Starter
−
generator defective (Check
for sheared armature drive shaft
through air inlet screen)
Replace sheared drive shaft (Refer
to manufacturer ’s publication
−
Ref.
Sec. 01
−
00, Table 201)
Voltage regulator or *GCU
defective
Replace voltage regulator or *GCU.
Voltage regulator or *GCU
incorrectly adjusted
Adjust voltage regulator or *GCU.
Overvoltage relay defective or
*GCU
Replace overvoltage relay or *GCU.
GEN
−
OFF
switch defective
Replace switch.
Defective wiring
Repair or replace defective wiring.
*Defective aft/fwd line contactor
*Replace aft/fwd line contactor.
Ammeter indication off
−
scale below
zero; engine not operating and
GEN
−
OFF switch is on
Defective reverse current relay or
*GCU
Replace reverse current relay or
*GCU.
GEN
−
OUT indicator light on;
voltage lower than normal when
engine is operating
Weak generator field
Replace starter
−
generator.
Defective voltage regulator or
*GCU
Replace voltage regulator or *GCU.
Defective starter
−
generator
Replace or repair starter
−
generator.
Incorrectly adjusted voltage
regulator or *GCU
Adjust voltage regulator or *GCU.
Fluctuating current indication on
ammeter
Unstable voltage regulator or *GCU
Replace voltage regulator or *GCU.
Brushes excessively worn
Replace starter
−
generator brushes.
Defective starter
−
generator
Replace or repair starter
−
generator.
Loose ammeter circuit wiring or
defective resistor R500 if installed
(R500 used with early model
instrument clusters
−
369D S/N
003
−
723 only)
Check ammeter circuit connections
and resistor R500 if installed. Repair
or replace as necessary.
Содержание 369-500
Страница 14: ......
Страница 30: ......
Страница 82: ......
Страница 94: ......
Страница 106: ......
Страница 116: ......
Страница 134: ......
Страница 150: ......
Страница 162: ......
Страница 168: ......
Страница 178: ......
Страница 226: ......
Страница 232: ......
Страница 244: ......
Страница 346: ......
Страница 416: ......
Страница 444: ......
Страница 458: ......
Страница 472: ......
Страница 490: ......
Страница 536: ......
Страница 560: ......
Страница 578: ......
Страница 604: ......
Страница 612: ......
Страница 616: ......
Страница 628: ......
Страница 654: ......
Страница 678: ......
Страница 706: ......