CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
95-30-00
Page 103
Revision 13
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
7. Analog/Digital Torque Indicator Troubleshooting
Table 106. Analog/Digital Torque Indicator Troubleshooting
Symptom
Probable Trouble
Corrective Action
Indicator inoperative
Defective oil pressure transducer
Replace transducer (Ref. Engine
Torque and/or Oil Pressure
Transducer Replacement).
Instrument circuit breaker CB101
open
Reset circuit breaker CB101.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
Incorrect reading
Defective indicator
Remove and replace indicator.
8. Engine Oil Temperature
−
Oil Pressure Indicator Troubleshooting
Table 107. Oil Press, Oil Temp Indicator Troubleshooting
Symptom
Probable Trouble
Corrective Action
Pressure indicator fails to operate.
No readings or intermittent
readings
Defective indicator
Remove and replace indicator.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
No out put from oil pressure
transducer
Defective transducer
Remove and replace transducer.
Oil temperature fails to operated.
No reading or intermittent reading
Open circuit in oil temperature bulb
Remove and replace oil temperature
bulb.
Defective wiring
Repair as necessary.
9. Analog Indicator (Torque, TOT)
Table 108. Analog Indicator (Torque, TOT) Troubleshooting
Symptom
Probable Trouble
Corrective Action
Torque
Indicator inoperative
Defective oil pressure transducer
Replace transducer
Instrument circuit breaker CB101
open
Reset circuit breaker CB101.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
Incorrect reading
Defective indicator
Remove and replace indicator.
Содержание 369-500
Страница 14: ......
Страница 30: ......
Страница 82: ......
Страница 94: ......
Страница 106: ......
Страница 116: ......
Страница 134: ......
Страница 150: ......
Страница 162: ......
Страница 168: ......
Страница 178: ......
Страница 226: ......
Страница 232: ......
Страница 244: ......
Страница 346: ......
Страница 416: ......
Страница 444: ......
Страница 458: ......
Страница 472: ......
Страница 490: ......
Страница 536: ......
Страница 560: ......
Страница 578: ......
Страница 604: ......
Страница 612: ......
Страница 616: ......
Страница 628: ......
Страница 654: ......
Страница 678: ......
Страница 706: ......