CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
Page 108
Revision 11
95-00-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Table 103. Instrument Troubleshooting (Cont.)
Airspeed Indicator
Pointer needle oscillates
Leak in line or lines
Tighten loose connections. Remove
and replace damaged line.
Defective indicator
Remove and replace indicator.
Water in system, clogged or dirty
pitot pressure or static lines.
Disconnect lines from instrument and
clear lines of obstructions.
Pointer does not operate
Pitot line not connected
Connect pitot line to indicator.
Vertical Speed Indicator
Needle off zero
Improper mechanical adjustment of
needle
Reset needle to zero by turn
adjustment screw.
Needle oscillates
Leak in static pressure line
Tighten loose connection. Remove
and replace damaged lines.
Defective Indicator
Remove and replace indicator.
N
1
Tachometer Indicator
Rpm indicator fails to operate. No
readings or intermittent readings
Defective indicator
Remove and replace indicator.
Defective tach generator
Remove and replace tach generator.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
N
2
/N
R
or N
R
/N
P
Tachometer Indicator
Rpm indicator fails to operate. No
readings or intermittent readings
Defective indicator
Remove and replace indicator.
Defective tach generator
Remove and replace tach generator.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
Torque Indicator
Indicator inoperative
Defective oil pressure transducer
Replace transducer
Instrument circuit breaker CB101
open
Reset circuit breaker CB101.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
Incorrect reading
Defective indicator
Remove and replace indicator.
Analog/Digital Torque Indicator
Indicator inoperative
Defective oil pressure transducer
Replace transducer
Instrument circuit breaker CB101
open
Reset circuit breaker CB101.
Loose wiring, disconnected
connector or defective ground
terminal
Check continuity through wiring and
connector. Repair as necessary.
Incorrect reading
Defective indicator
Remove and replace indicator.
Содержание 369-500
Страница 14: ......
Страница 30: ......
Страница 82: ......
Страница 94: ......
Страница 106: ......
Страница 116: ......
Страница 134: ......
Страница 150: ......
Страница 162: ......
Страница 168: ......
Страница 178: ......
Страница 226: ......
Страница 232: ......
Страница 244: ......
Страница 346: ......
Страница 416: ......
Страница 444: ......
Страница 458: ......
Страница 472: ......
Страница 490: ......
Страница 536: ......
Страница 560: ......
Страница 578: ......
Страница 604: ......
Страница 612: ......
Страница 616: ......
Страница 628: ......
Страница 654: ......
Страница 678: ......
Страница 706: ......