CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
96-00-00
Page 203
Revision 11
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Before removing or installing components of electrical system, ensure that electrical power is OFF.
If units are not immediately replaced, ensure all electrical connectors are suitably capped and
stowed and all loose cable ends are properly insulated and stowed to prevent possibility of
shorting. Serious injury or death could result from voltages present in electrical systems.
Before troubleshooting electrical system, ensure proper configuration of helicopter. Refer to Section
96-10-00 to verify current helicopter charging system components.
Table 201. Troubleshooting Electrical System
Symptom
Probable Trouble
Corrective Action
Battery fails to energize electrical
circuits
Defective BATTERY
−
OFF
−
EXT
PWR switch
Replace switch.
Defective battery relay
Replace battery relay.
Battery discharged
Install serviceable battery.
K200 Battery Hi Temp relay
Replace Battery Hi Temp relay.
Discharged battery
Charging rate incorrectly set
Adjust voltage regulator or *GCU.
Battery idle to long
Install serviceable battery.
Excessive corrosion on battery
terminals
Exposure to water or corrosive
fluids
Clean terminals; coat with
non
−
corrosive grease.
Battery overheats and/or
discharges smoke
Charging rate to high
Adjust voltage regulator or *GCU.
Loose battery terminal links, straps
or screws
Repair battery as necessary.
Damaged or defective battery
Repair or replace battery.
Starter
−
generator fails to function
when START switch pressed
Circuit breaker out
Reset circuit breaker.
Start relay defective
Replace start relay.
Battery relay defective
Replace battery relay.
APU relay defective
Replace APU relay.
Discharged battery
Install serviceable battery.
APU, reverse polarity, diode open
Replace diode.
Starter
−
generator defective
Replace starter
−
generator.
START switch or wiring defective
Replace switch, or repair defective
wiring.
*Defective
fwd line contactor
*Replace fwd line contactor.
WARNING
Содержание 369-500
Страница 14: ......
Страница 30: ......
Страница 82: ......
Страница 94: ......
Страница 106: ......
Страница 116: ......
Страница 134: ......
Страница 150: ......
Страница 162: ......
Страница 168: ......
Страница 178: ......
Страница 226: ......
Страница 232: ......
Страница 244: ......
Страница 346: ......
Страница 416: ......
Страница 444: ......
Страница 458: ......
Страница 472: ......
Страница 490: ......
Страница 536: ......
Страница 560: ......
Страница 578: ......
Страница 604: ......
Страница 612: ......
Страница 616: ......
Страница 628: ......
Страница 654: ......
Страница 678: ......
Страница 706: ......