POWER TRAIN INSTRUMENTS
FAULT ISOLATION
1. Power Train Instruments Fault Isolation
The following tables are to be used in trouble
shooting the power train instruments.
2. Tachometer Generator Troubleshooting
Table 101. Tachometer Indicating Systems
Symptom
Probable Trouble
Corrective Action
Excessive scale error (low reading)
Weak magnets in tachometer
Replace indicator.
Excessive scale error (high
reading)
Weak restraining spring in
tachometer indicator
Replace indicator.
Pointer off zero position with
engine inoperative
Pointer shifted
Replace indicator.
No reading or intermittent reading
Loose wiring, disconnected
connector or defective ground
terminal connection
Check continuity through wiring and
connectors. Repair as necessary.
Defective tachometer indicator or
generator
Replace defective indicator or
generator.
Defective ground connection on
tachometer generator
Check for electrical bond between
tachometer generator mounting
flange and engine pad stud.
3. TOT Indicating System Troubleshooting
Table 102. TOT Indicating System
Symptom
Probable Trouble
Corrective Action
No reading on indicator
Loose connection
Check and tighten all connections.
Defective airframe thermocouple
harness
Replace or repair thermocouple
harness.
Defective engine thermocouple
harness
Replace engine thermocouple
harness (Ref. applicable Allison
Engine Operation and Maintenance
Manual, Table 201, 01
−
00
−
00).
Defective indicator
Replace indicator.
Open adjustable resistor R4
Replace resistor.
Erratic reading on indicator
Defective indicator
Replace indicator.
Defective connections or resistor
R4 on TB9 at back of instrument
Repair connections or replace
resistor.
Incorrect reading on indicator
TOT indicating system out of
calibration
Perform TOT Indicating System
Calibration.
Содержание 369-500
Страница 14: ......
Страница 30: ......
Страница 82: ......
Страница 94: ......
Страница 106: ......
Страница 116: ......
Страница 134: ......
Страница 150: ......
Страница 162: ......
Страница 168: ......
Страница 178: ......
Страница 226: ......
Страница 232: ......
Страница 244: ......
Страница 346: ......
Страница 416: ......
Страница 444: ......
Страница 458: ......
Страница 472: ......
Страница 490: ......
Страница 536: ......
Страница 560: ......
Страница 578: ......
Страница 604: ......
Страница 612: ......
Страница 616: ......
Страница 628: ......
Страница 654: ......
Страница 678: ......
Страница 706: ......