SPECIFICATIONS - Section 2
MTS-1700 SERIES OPERATION AND REFERENCE MANUAL 2-3
CU A002 15A
MANTA TEST SYSTEMS
•
Time measurement:
Measures fault interval from either internal or external start trigger
0 -99999 sec or 0 - 99999 cycles, autoranging scale
best resolution: 0.1 ms/ 0.1 cycles
accuracy: 0-9.9999sec scale: ±0.5ms ±1 least significant digit
all other scales: ±0.005% ±1 least significant digit
two-wire pulse timing mode
•
Frequency measurement: power line frequency measurement (accuracy & resolution: ±0.01Hz)
variable frequency value displayed to 0.001Hz resolution
2.4 COMPUTED MEASUREMENTS
•
Impedance (V÷I, V÷2I , V÷1.732I, V÷((1+k)I) ) with programmable k-factor
•
Resistance (Re(V÷I), Re(V÷2I) , Re(V÷1.732I), Re(V÷((1+k)I)) ) with programmable k-factor
•
Reactance (Im(V÷I), Im(V÷2I) , Im(V÷1.732I), Im(V÷((1+k)I)) with programmable k-factor
•
Single phase power (Watts, Vars, VA, Power Factor)
•
I1÷I2, I2÷I1, (I1-I2)÷((I1+I2)÷2), I2÷((2I1+I2)÷2), with programmable CT tap values for I1, I2
•
%harmonic current
•
V÷Hz
•
Breaker advance time, breaker closing angle
2.5 STATIC/DYNAMIC TESTING CAPABILITIES
•
Phase to neutral faults
•
Phase to phase faults
•
Three phase faults
•
Two phase to neutral faults
•
Phase, frequency, voltage and current stepping
•
Phase, frequency, voltage and current ramping with adjustable rate of change
•
Presettable fault durations, 0 -99.9999 sec
•
Programmable auto-reclose time delay and reclose-into-fault events
•
Programmable breaker time
•
Three-pole and single-pole tripping
•
Programmable PT location simulation
2.6 FAULT PLAYBACK
•
Ability to accept fault data from fault recorders, EMTP simulation outputs, or user-defined waveforms
•
Sample rate:
programmable 2-30 kHz
•
Record length:
8 bit: 8000 samples per each of four channels (six channels available when
MTS-1720 is also used)
14 bit: 60k samples per each of four channels (six channels available when
MTS-1720 is also used)
•
Resolution: 8 bit: 8 bit d 12 bit scaling
14 bit: 14 bit d 16 bit scaling
•
Peak output levels: ±230.5V for voltage channels
±42.4A for current channels
Содержание MTS-1700 SERIES
Страница 30: ...TABLE OF CONTENTS xxx MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 38: ...INTRODUCTION Section 1 1 8 MTS 1700SERIESOPERATIONANDREFERENCEMANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 44: ...SPECIFICATIONS Section 2 2 6 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 248: ...FAULT PLAYBACK Section 7 7 12 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 262: ...SERVICING Section 8 8 14 MTS 1700 SERIES OPERATION ANDREFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 320: ...PROGRAMMABLE DIGITAL I O CHANNELS A 14 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 340: ...E 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 344: ...GLOSSARY F 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...