MTS-1750 HIGH CURRENT SOURCE - Section 10
10-6 MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
The second line will indicate the phases for which an MTS-1750 was expected, but not found. The allowable
equipment configurations and current modes are:
•
MTS-1710 + MTS-1750 (in I1-LOW current mode)
•
MTS-1710 + MTS-1720 + (3) MTS-1750s (in I3-WYE or I3-PARALLEL current
mode)
10.4.1.3 OPERATION WITH THE MTS-1710 + MTS-1750 CONFIGURATION.
10.4.1.3.1 Current Adjustment and Display
Current is selected and adjusted, just as in I1-LOW current mode. The maximum output is 150A. The
measured value on the [VALUE DISPLAY] is the total paralleled current through the load.
The fault current can be set without applying it to the load by using the fault current preset feature (see
Section 4.6.9).
10.4.1.3.2 RS-232 Programming
The single current output is programmed (similar to the I1-LOW current mode) using the AI1, IFI, IFF, IRR,
IPO commands (see Section 6.2.6.1), with the exception that the maximum value is 150A.
10.4.2 MTS-1720 +MTS-1720 + (3) MTS-1750s Configuration
This combination allows up to 450A single phase or 150A per phase, three-phase from the current outputs.
10.4.2.1 CONNECTIONS AND POWER.
• Turn off the MTS-1710, MTS-1720 and MTS-1750. Connect the AC input power and safety ground to
all instruments.
• Connect the [COM3 SLAVE CURRENT] port of the MTS-1710 to the MTS-1720 [COM1 TO MTS-
1710 PORT], using the RS-232 cable provided. (Use only the Manta Test Systems supplied cable).
This is NOT a standard RS-232 cable).
• Connect the MTS-1720 current output to the MTS-1710 slave current input using the high current
cable provided. (On older systems, the connector was a blue locking ring. Retract the blue locking
ring before inserting. After inserting the connector in the mating socket, twist clockwise to lock. Turn
the blue inner locking ring clockwise to lock the connector in place).
• Connect the [MTS-1750 CH A] port of the MTS-1710 to the [CONTROL] connector on the rear panel
of the MTS-1750 that will be channel A, as shown in Figure 10.6 using the provided cable.
• Connect the [MTS-1750 CH B] port of the MTS-1720 to the [CONTROL] connector on the rear panel
of the MTS-1750 that will be channel B, as shown in Figure 10.6 using the provided cable.
• Connect the [MTS-1750 CH C] port of the MTS-1720 to the [CONTROL] connector on the rear panel
of the MTS-1750 that will be channel C, as shown in Figure 10.6 using the provided cable.
Содержание MTS-1700 SERIES
Страница 30: ...TABLE OF CONTENTS xxx MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 38: ...INTRODUCTION Section 1 1 8 MTS 1700SERIESOPERATIONANDREFERENCEMANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 44: ...SPECIFICATIONS Section 2 2 6 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 248: ...FAULT PLAYBACK Section 7 7 12 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 262: ...SERVICING Section 8 8 14 MTS 1700 SERIES OPERATION ANDREFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 320: ...PROGRAMMABLE DIGITAL I O CHANNELS A 14 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 340: ...E 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 344: ...GLOSSARY F 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...