RS-232C INTERFACE - Section 6
MTS-1700 SERIES OPERATION AND REFERENCE MANUAL 6-27
CU A002 15A
MANTA TEST SYSTEMS
To set up the programmable waveform, the following commands should be used:
REM
<- remote control mode
PWC3
<- reset to start of waveform data table
PWD1
<- first data point, -Max output at 0 degrees
!1
<- second data point (use repeat last command feature)
!128
<- data point at 0.5 degrees
!193
<- data point at 0.75 degrees
!193
<- data point at 1 degree
!257
!321
<- data point at 1.5 degrees
!321
..etc.
(note that some points are repeated due to 8-bit amplitude resolution)
.
.
!16379
<- data point at 179 degrees
!16380
<- data point at 179.25 degrees
!16381
<- data point at 179.5 degrees
!16382
!16383
<- data point at 180 degrees (+Max output)
!16383
!16382
<- data point at 180.5 degrees
!16381
!16381
<- data point at 181 degrees
..etc.
(triangular waveform definition continued)
.
.
!321
<- data point at 358.25 degrees
!321
<- data point at 358.50 degrees
!257
!193
<- data point at 359.00 degrees
!193
!128
<- data point at 359.50 degrees
!1
<- last data point at 359.75 degrees
To enable the programmable waveform, send the following commands:
PWC1
<- enable programmable waveform
RCR18.6
<- rate=18.6kHz, filter at 9.3kHz
LOC
<- local control mode
Now the amplitude, phase and frequency of the waveform may be controlled from the front panel (or RS-
232C interface, if desired).
To return to normal sine wave output, send the following commands:
REM
<- remote control mode
PWC0
<- programmable waveform off
LOC
<- return to local control mode
Содержание MTS-1700 SERIES
Страница 30: ...TABLE OF CONTENTS xxx MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 38: ...INTRODUCTION Section 1 1 8 MTS 1700SERIESOPERATIONANDREFERENCEMANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 44: ...SPECIFICATIONS Section 2 2 6 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 248: ...FAULT PLAYBACK Section 7 7 12 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 262: ...SERVICING Section 8 8 14 MTS 1700 SERIES OPERATION ANDREFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 320: ...PROGRAMMABLE DIGITAL I O CHANNELS A 14 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 340: ...E 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 344: ...GLOSSARY F 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...