![Manta MTS-1700 SERIES Скачать руководство пользователя страница 120](http://html1.mh-extra.com/html/manta/mts-1700-series/mts-1700-series_operation-and-reference-manual_1723616120.webp)
DETAILED OPERATION - Section 4
4-30
MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
4.6.10.6
PARALLELING MORE THAN TWO (MTS-1710 + MTS-1720) SYSTEMS.
Higher currents and higher VA output can be obtained by simply connecting more MTS-1710 + MTS-1720
systems together. The MTS-1720 systems are optional.
NOTE:
External transient protection is required when paralleling together more than three MTS-1700
systems. Please contact Manta Test Systems Technical Support for more details.
4.6.10.6.1
Single phase high current
FIGURE 4.22 PARALLELING MORE THAN TWO (MTS-1710 + MTS-1720)
SYSTEMS SINGLE PHASE LOAD
For current paralleling:
1.
Connect the multi-system synchronization cable at the rear, as shown in Figure 4.24.
2.
Select I3-PARALLEL current mode on all MTS-1710s.
3.
Connect the MTS-1710 + MTS-1720 current outputs, as shown in the diagram above.
4.
To synchronize the fault initiation/termination, connect the start/stop trigger inputs, as shown.
5. Set the current amplitude and phase angle on each MTS-1710/1720 system individually (normally set
to the same on both). The current through the load will be the vectorial sum of the paralleled currents.
TRIP
LOAD
Multi-system
sync connection
(rear)
Note: Select I3P (PARALLEL) current mode on all MTS-1710 systems
Multi-system
sync connection
(rear)
To next
MTS-1700 system
I3- PARALLEL
Содержание MTS-1700 SERIES
Страница 30: ...TABLE OF CONTENTS xxx MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 38: ...INTRODUCTION Section 1 1 8 MTS 1700SERIESOPERATIONANDREFERENCEMANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 44: ...SPECIFICATIONS Section 2 2 6 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 248: ...FAULT PLAYBACK Section 7 7 12 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 262: ...SERVICING Section 8 8 14 MTS 1700 SERIES OPERATION ANDREFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 320: ...PROGRAMMABLE DIGITAL I O CHANNELS A 14 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 340: ...E 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 344: ...GLOSSARY F 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...