![Manta MTS-1700 SERIES Скачать руководство пользователя страница 206](http://html1.mh-extra.com/html/manta/mts-1700-series/mts-1700-series_operation-and-reference-manual_1723616206.webp)
RS-232C INTERFACE - Section 6
6-20 MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
BRT#
Baud Rate
•
Sets the COM1 baud rate
•
Valid values are 0 - 11
0 - 300 baud
6 - 3600 baud
1 - 600 baud
7 - 4800 baud
2 - 1200 baud
8 - 7200 baud
3 - 1800 baud
9 - 9600 baud
4 - 2000 baud
10 - 19200 baud
5 - 2400 baud
11 - 38400 baud
•
The change in baud rate is effective immediately following the execution of the
BRT command.
•
The new setting is retained in non-volatile memory, and takes effect until
changed again.
6.2.10 Timer & Tone Control
Command
Description
XST
External Timer Start
•
This command selects External timer start mode (see Section 5.3)
IST Internal
Timer
Start
•
This command selects Internal timer start mode (see Section 5.3)
TON#
Tone Enable/Disable
•
This command controls the audible tone for indicating contact and voltage
sensed on the [EXTERNAL STOP] terminals, and for indicating entry into
postfault state (See Section 4.11).
It also controls the overload warning tone feature.
•
Valid values are 0 to 4
0 - disable tone for external stop and postfault indication
1 - enable tone for external stop and postfault indication
2 - disable warning tone
3 - enable warning tone
4 - beep tone momentarily
6.2.11 Display/Print Commands
Command
Description
DCU# Display
Current
•
Selects current on the [VALUE DISPLAY]
•
If no argument is specified, this command brings up the last selected current
parameter on the [VALUE DISPLAY]
•
DCU1 and DCU2 select I1 and I2 respectively to be displayed in I1&I2 current
mode.
•
DCU3, DCU4 and DCU5 selects I2, %-harmonic and DC-AMPS current
respectively to be displayed in I2-Harmonic current mode.
Содержание MTS-1700 SERIES
Страница 30: ...TABLE OF CONTENTS xxx MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 38: ...INTRODUCTION Section 1 1 8 MTS 1700SERIESOPERATIONANDREFERENCEMANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 44: ...SPECIFICATIONS Section 2 2 6 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 248: ...FAULT PLAYBACK Section 7 7 12 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 262: ...SERVICING Section 8 8 14 MTS 1700 SERIES OPERATION ANDREFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 320: ...PROGRAMMABLE DIGITAL I O CHANNELS A 14 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 340: ...E 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...
Страница 344: ...GLOSSARY F 4 MTS 1700 SERIES OPERATION AND REFERENCE MANUAL MANTA TEST SYSTEMS CU A002 15A ...