The following safety distances to overhead electrical lines must be
maintained:
Nominal voltage
Minimum
safe dis-
tance
Unit
up to 1 kV
1.00
m
up to 1 kV
3.28
ft
above 1 kV up to 110 kV
3.00
m
above 1 kV up to 110 kV
9.84
ft
above 110 kV up to 220 kV
4.00
m
above 110 kV up to 220 kV
13.12
ft
above 220 kV up to 380 kV
5.00
m
above 220 kV up to 380 kV
16.4
ft
Nominal voltage unknown
5.00
m
Nominal voltage unknown
16.4
ft
Safety distances to overhead elec-
trical lines
Product description
27.04.2020
140.5.204 Telescopic crane
56
Fo
r
Reference