Step 4.
Lock the hard disk drive into place by closing the release lever.
After you install the hard disk drive backplane, complete the following steps:
1. Install the cover onto the compute node (see “Installing the compute node cover” on page 644 for
instructions).
2. Install the compute node into the chassis (see “Installing a compute node in a chassis” on page 639
for instructions).
Removing a hot-swap hard disk drive
Use this information to remove a hot-swap hard disk drive.
Before you remove a hot-swap hard disk drive, complete the following steps:
1. Back up all important data before you make changes to hard disk drives.
2. Read “Safety” on page iii and “Installation guidelines” on page 637.
The compute node has two hard disk drive bays for hot-swap hard disk devices. To remove a hot-swap hard
disk drive, complete the following steps.
0000
0000
0000
0000
00000000000
00000000000
00000000000
00000000000
00000000000
00000000000
Release
latch
Hard disk
drive
assembly
Hard disk
drive bay filler
Drive
handle
Activity
LED
(green)
Error
LED
(amber)
Step 1.
Press the release latch (orange) on the hard disk drive to release the drive handle.
Step 2.
Pull the release handle to remove the drive from the bay.
If you are instructed to return the hard disk drive, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a hot-swap hard disk drive
Use this information to install a hot-swap hard disk drive.
Before you install the hot-swap hard disk drive, read “Safety” on page iii and “Installation guidelines” on
page 637.
The compute node has two SAS or SATA hard disk drive bays for installing hot-swap hard disk drives, such
as hot-swap SAS hard disk drives. One hard disk drive might already be installed in the compute node
in hard disk drive bay 0. If the compute node is equipped with one hard disk drive, you can install an
Installing, removing, and replacing compute node components
663
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......