2. Reboot the system. If problem persists, contact Support.
•
S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation:
PCI SERR Detected
Severity
Error
User Response
Complete the following steps:
1. If this compute node and/or any attached cables were recently installed, moved, serviced or
upgraded,
a. Reseat the adapter and any attached cables.
b. Reload the device driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe
Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check the IBM support site for an applicable device driver, firmware update, or other information
that applies to this error. Load the new device driver and install any required firmware updates.
3. If the problem persists, remove the adapter. If system reboots successfully without the adapter,
replace that adapter.
4.
Replace the processor.
Related links
–
“Removing an I/O expansion adapter” on page 666
–
“Installing an I/O expansion adapter” on page 667
–
“Using the Setup utility” on page 24
–
“Updating firmware and device drivers” on page 21
–
“Removing a microprocessor and heat sink” on page 675
–
“Installing a microprocessor and heat sink” on page 678
•
S.2018001 [S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation:
PCIe Uncorrected Error Detected
Severity
Error
User Response
Complete the following steps:
1. If this compute node and/or any attached cables were recently installed, moved, serviced or
upgraded:
a. Reseat the adapter and any attached cables.
b. Reload the device driver.
596
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...