3. If error recurs, or socket damage is found, replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 675
–
“Installing a microprocessor and heat sink” on page 678
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
S.680B9 [S.680B9] External QPI Link Failure Detected.
Explanation:
External QPI Link Failure Detected
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Inspect the processor socket for foreign debris or damage. If debris is found, remove the debris.
3. If error recurs, or socket damage is found, replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 675
–
“Installing a microprocessor and heat sink” on page 678
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation:
Processor Self Test Failure Detected
Severity
Warning
User Response
Complete the following steps:
1. If the processor or firmware was just updated, check the IBM support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. If there are multiple Processors, swap Processors to move affected processor to another
processor socket and retry. If problem follows the affected processor, or this is a single processor
system, replace the processor. Inspect the processor socket on each processor removal and
replace system board first if the processor socket is damaged or mis-aligned pins are found.
3.
Replace the system board.
Related links
–
“Removing a microprocessor and heat sink” on page 675
–
“Installing a microprocessor and heat sink” on page 678
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
605
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...