Alert Category
System - Remote Login
SNMP Trap ID
30
CIM Information
Prefix:
IMM
ID:
0141
User Response
Make sure that the correct login ID and password are being used.
•
80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
A voltage has dropped below its specified threshold.
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix:
PLAT
ID:
0480
User Response
Use one of the following procedures:
– If the specified sensor is Planar 3.3V or Planar 5V, replace the system board.
– If the specified sensor is Planar 12V, check the Chassis Management Module or Flex System
Manager event log for power-supply-related issues, and resolve those issues. If the problem
remains, replace the system board.
•
80010202-2801ffff : Sensor Planar VBAT has detected low battery voltage.
The CMOS battery voltage has dropped below its specified threshold.
May also be shown as 800102022801ffff or 0x800102022801ffff
Severity
Error
Serviceable
Yes
297
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...