No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0244
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
•
806f0a13-3104ffff : A Fatal Bus Error has occurred on bus PEN Slot4.
A fatal bus error has been detected in the I/O expansion adapter in PCIe adapter slot 4 in the PCI
expansion unit.
May also be shown as 806f0a133104ffff or 0x806f0a133104ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0244
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
•
81010202-0701ffff : Sensor [NumericSensorElementName] has detected that a voltage is no
longer going low.
A previously low voltage has returned to above its specified threshold (sensor Planar 12V, Planar 3.3V, or
Planar 5V).
May also be shown as 810102020701ffff or 0x810102020701ffff
458
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...