Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related links
–
–
–
•
409-906-000 : Nvidia::DiagnosticServiceProvider::Binomial Test Failed
Nvidia GPU Binomial Test Failed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle
the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of
system issues can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related links
–
–
–
171
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...