Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0266
User Response
Complete the following steps until the problem is solved:
1. Make sure that the cable from the light path LED card to the system board is securely connected.
2. Replace the light path diagnostics panel.
•
806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by IPMI Watchdog.
The IPMI watchdog timer has expired. The compute node has restarted.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0370
User Response
Information only; no action is required.
•
806f0125-1f03ffff : LOM detected as absent.
The is no LAN on Motherboard (LOM) detected on this system board.
May also be shown as 806f01251f03ffff or 0x806f01251f03ffff
Severity
Info
Serviceable
No
Automatically notify support
373
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...