Hard disk
drive backplane
Step 1.
Remove the cover (see “Removing the compute node cover” on page 643).
Step 2.
Unlatch and slide out slightly the hot-swap hard disk drive and hard disk drive bay filler, (just
enough to disengage the drive or filler).
Step 3.
Lift out the hard disk drive backplane.
If you are instructed to return the hard disk drive backplane, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing the hard disk drive backplane
Use this information to install the hard disk drive backplane.
Before you install the hard disk drive backplane, complete the following steps:
1. Read “Safety” on page iii and “Installation guidelines” on page 637.
2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node
from a chassis” on page 639 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
To install the hard disk drive backplane, complete the following steps.
000
000
000
000
000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Hard disk
drive backplane
Step 1.
Remove the cover (see “Removing the compute node cover” on page 643).
Step 2.
Align the backplane with the hard disk drive cage and the connector on the system board and
press the backplane into position until it is fully seated in the connector.
Step 3.
Slide the hard disk drive and hard disk drive bay filler into the bay until it is firmly seated in the
connector.
662
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...