1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat the adapter and any attached cables.
2. Move the adapter to a different system slot, if available.
3. Check the IBM support site for any applicable service bulletin or UEFI or adapter firmware
update that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use
special utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ASU Utility.
4.
Replace the adapter.
Related links
–
“Removing an I/O expansion adapter” on page 666
–
“Installing an I/O expansion adapter” on page 667
–
“Using the Setup utility” on page 24
•
I.3048005 [I.3048005] UEFI has booted from the backup flash bank.
Explanation:
Booting Backup UEFI Image
Severity
Info
User Response
Complete the following steps:
Return the system to primary bank.
Related links
–
“Recovering a UEFI image” on page 22
•
I.3808004 [I.3808004] The IMM System Event log (SEL) is full.
Explanation:
IPMI System Event Log is Full
Severity
Info
User Response
Complete the following steps:
1. Use the IMM Web Interface to clear the event log.
2. If IMM communication is unavailable, use the Setup Utility to access the System Event Logs
Menu and choose Clear IMM System Event Log and Restart Server.
Related links
–
“Using the Setup utility” on page 24
•
I.3818001 [I.3818001] The firmware image capsule signature for the currently booted flash bank
is invalid.
592
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...