Step 3.
Under
Storage
, select
ServeRAID C105
.
The following illustration shows the Setup utility main menu.
Step 4.
Under
Configuration Options
, select
Virtual Drive Management > Create Configuration
.
Step 5.
On the
Create Configuration
screen, select the RAID level for the array that you want to create:
• RAID0 is the only option available if there is just one hard disk drive installed.
• RAID0 and RAID1 are available if two hard disk drives are installed.
Step 6.
On the
Create Configuration
screen, select
Select Drives
. The
Select Drives
screen is displayed.