Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0522
User Response
Information only; no action required.
•
80070217-0b05ffff : Sensor ETE Fault has transitioned to critical from a less severe state.
A failure has been detected in the interposer card.
May also be shown as 800702170b05ffff or 0x800702170b05ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0522
User Response
1. Make sure that the interposer card is connected correctly. If the error remains, check the log
for faults on the attached expansion unit and resolve them.
2. Replace the attached expansion unit.
•
80070217-0b81ffff : Sensor PEN FHR Empty has transitioned to critical from a less severe state.
The Full Height Riser Card in the PCIe Expansion Node has been detected as missing. The PCIe
Expansion Node will not power on without this card installed.
May also be shown as 800702170b81ffff or 0x800702170b81ffff
315
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...