Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0522
User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module
or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow
at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
•
80070201-3104ffff : Sensor PCIE 4 Overtemp has transitioned to critical from a less severe state.
The temperature of the PCI expansion unit PCIe Card4 has exceeded its specified threshold.
May also be shown as 800702013104ffff or 0x800702013104ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0522
User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module
or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow
at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
•
80070202-0701ffff : Sensor Planar Fault has gone to Critical state from a less severe state.
A failure has been detected in the system board.
312
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...