3.
Replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
S.3058004 [S.3058004] A Three Strike boot failure has occurred. The system has booted with
default UEFI settings.
Explanation:
POST failure has occurred! System booted with default settings.
Severity
Error
User Response
Complete the following steps:
1. This event resets UEFI to the default settings for the next boot. If successful, the Setup Utility is
displayed. The original UEFI settings are still present.
2. If you did not intentionally trigger the reboots, check logs for probable cause.
3. Undo recent system changes (settings or devices added). If there were no recent system
changes, remove all options, and then remove the CMOS battery for 30 seconds to clear CMOS
contents. Verify that the system boots. Then, re-install the options one at a time to locate the
problem.
4. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
5.
Update the UEFI firmware.
6. Remove and re-install CMOS battery for 30 seconds to clear CMOS contents
7.
Replace the system board.
Related links
–
“Removing the CMOS battery” on page 650
–
“Installing the CMOS battery” on page 651
–
“Updating firmware and device drivers” on page 21
–
“Using the Setup utility” on page 24
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
S.3060007 [S.3060007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2.
Update the UEFI image.
599
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...