Severity
An indication of the level of concern for the condition. In the event log, the severity is abbreviated to the
first character. The following severities can be displayed:
•
Info:
The event was recorded for audit purposes, usually a user action or a change of states that is
normal behavior.
•
Warning:
The event is not as severe as an error, but if possible, the condition should be corrected
before it becomes an error. It might also be a condition that requires additional monitoring or
maintenance.
•
Error:
The event is a failure or critical condition that impairs service or an expected function.
Alert Category
Similar events are grouped in categories. The alert category is in the following format:
severity
-
device component
severity
is one of the following severity levels:
•
Critical:
A key component in the server is no longer functioning.
•
Warning:
The event might progress to a critical level.
•
System:
The event is the result of a system error or a configuration change.
device component
is the specific device in the compute node that caused the event to be generated.
Serviceable
Whether user action is required to correct the problem.
CIM Information
The prefix of the message ID and the sequence number that is used by the CIM message registry.
SNMP Trap ID
The SNMP trap ID that is found in the SNMP alert management information base (MIB).
Automatically notify Support
If this field is set to
Yes
and you have enabled Electronic Service Agent (ESA) on Flex System Manager
management software (if installed), Support will be notified automatically if the event is generated.
If Flex System Manager management software is not installed, you can enable Support from the
CMM web interface.
While you wait for Support to call, you can perform the recommended actions for the event.
User response
The actions that you should perform to solve the event.
Perform the steps listed in this section in the order shown until the problem is solved. After you perform
all of the actions that are described in this field, if you cannot solve the problem, contact Support.
Note:
This list includes error codes and messages that might not apply to this machine type and model.
IMM Events that automatically notify Support
You can configure the IBM Flex System Manager or the CMM to automatically notify Support (also known as
call home
) if certain types of errors are encountered. If you have configured this function, see the table for
a list of events that automatically notify Support.
224
Flex System x220 Compute Node Installation and Service Guide
Содержание Flex System x220
Страница 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Страница 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Страница 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Страница 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Страница 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Страница 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Страница 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Страница 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Страница 713: ......
Страница 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...